Review




Structured Review

Clinical and Laboratory Standards Institute reference bmd panels
Reference Bmd Panels, supplied by Clinical and Laboratory Standards Institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/reference bmd panels/product/Clinical and Laboratory Standards Institute
Average 90 stars, based on 1 article reviews
reference bmd panels - by Bioz Stars, 2026-06
90/100 stars

Images



Similar Products

99
ATCC reference bmd etest p aeruginosa atcc 27853
Reference Bmd Etest P Aeruginosa Atcc 27853, supplied by ATCC, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/reference bmd etest p aeruginosa atcc 27853/product/ATCC
Average 99 stars, based on 1 article reviews
reference bmd etest p aeruginosa atcc 27853 - by Bioz Stars, 2026-06
99/100 stars
  Buy from Supplier

90
Thermo Fisher custom frozen reference bmd panels
Comparison of error rates for CAZ, LVX, MEM, MIN, and TMP-SMX DD as compared to <t>BMD,</t> all BCC isolates. VMEs, MEs, and MIs for DD compared to BMD were summed for assays performed on three MHA brands (Remel, HD, and BD). The table summarizes χ 2 analyses for <t>each</t> <t>antimicrobial,</t> testing whether errors are under- or over-represented for DD performed on three different MHA brands. P -value <0.05 was considered significant. Blue, agreement between methods; red, error between methods. #, number.
Custom Frozen Reference Bmd Panels, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/custom frozen reference bmd panels/product/Thermo Fisher
Average 90 stars, based on 1 article reviews
custom frozen reference bmd panels - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Laboratory Specialists Inc reference bmd
Example picture of A. baumannii read by reference <t>BMD</t> <t>and</t> <t>ComASP</t> (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).
Reference Bmd, supplied by Laboratory Specialists Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/reference bmd/product/Laboratory Specialists Inc
Average 90 stars, based on 1 article reviews
reference bmd - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Eurofins contribution to bmd reference testing
Example picture of A. baumannii read by reference <t>BMD</t> <t>and</t> <t>ComASP</t> (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).
Contribution To Bmd Reference Testing, supplied by Eurofins, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/contribution to bmd reference testing/product/Eurofins
Average 90 stars, based on 1 article reviews
contribution to bmd reference testing - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Gradientech bmd reference testing
Example picture of A. baumannii read by reference <t>BMD</t> <t>and</t> <t>ComASP</t> (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).
Bmd Reference Testing, supplied by Gradientech, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/bmd reference testing/product/Gradientech
Average 90 stars, based on 1 article reviews
bmd reference testing - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Clinical and Laboratory Standards Institute reference bmd panels
Example picture of A. baumannii read by reference <t>BMD</t> <t>and</t> <t>ComASP</t> (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).
Reference Bmd Panels, supplied by Clinical and Laboratory Standards Institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/reference bmd panels/product/Clinical and Laboratory Standards Institute
Average 90 stars, based on 1 article reviews
reference bmd panels - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Mindways Software bmd reference phantom mindways software
Example picture of A. baumannii read by reference <t>BMD</t> <t>and</t> <t>ComASP</t> (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).
Bmd Reference Phantom Mindways Software, supplied by Mindways Software, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/bmd reference phantom mindways software/product/Mindways Software
Average 90 stars, based on 1 article reviews
bmd reference phantom mindways software - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Thermo Fisher 96-well frozen reference broth microdilution (bmd) panels in cation-adjusted mueller-hinton broth (camhb)
Example picture of A. baumannii read by reference <t>BMD</t> <t>and</t> <t>ComASP</t> (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).
96 Well Frozen Reference Broth Microdilution (Bmd) Panels In Cation Adjusted Mueller Hinton Broth (Camhb), supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/96-well frozen reference broth microdilution (bmd) panels in cation-adjusted mueller-hinton broth (camhb)/product/Thermo Fisher
Average 90 stars, based on 1 article reviews
96-well frozen reference broth microdilution (bmd) panels in cation-adjusted mueller-hinton broth (camhb) - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


Comparison of error rates for CAZ, LVX, MEM, MIN, and TMP-SMX DD as compared to BMD, all BCC isolates. VMEs, MEs, and MIs for DD compared to BMD were summed for assays performed on three MHA brands (Remel, HD, and BD). The table summarizes χ 2 analyses for each antimicrobial, testing whether errors are under- or over-represented for DD performed on three different MHA brands. P -value <0.05 was considered significant. Blue, agreement between methods; red, error between methods. #, number.

Journal: Journal of Clinical Microbiology

Article Title: Evaluation of antimicrobial susceptibility testing methods for Burkholderia cepacia complex isolates from people with and without cystic fibrosis

doi: 10.1128/jcm.01480-24

Figure Lengend Snippet: Comparison of error rates for CAZ, LVX, MEM, MIN, and TMP-SMX DD as compared to BMD, all BCC isolates. VMEs, MEs, and MIs for DD compared to BMD were summed for assays performed on three MHA brands (Remel, HD, and BD). The table summarizes χ 2 analyses for each antimicrobial, testing whether errors are under- or over-represented for DD performed on three different MHA brands. P -value <0.05 was considered significant. Blue, agreement between methods; red, error between methods. #, number.

Article Snippet: For CF isolates, testing was performed from June 2022 to December 2022 using custom frozen reference BMD panels prepared by ThermoFisher with the same antimicrobial dilution ranges as listed above.

Techniques: Comparison

Comparison of error rates for CAZ, LVX, MEM, MIN, and TMP-SMX DD as compared to BMD, CF vs non-CF isolates. VMEs, MEs, and MIs for DD compared to BMD were summed for assays performed on three MHA brands (Remel, HD, and BD). The table summarizes χ 2 analyses for each antimicrobial, testing whether errors are under- or over-represented for DD performed on three different MHA brands. P -value <0.05 was considered significant, and values <0.05 are highlighted red in the table. Blue, agreement between methods; red, error between methods. #, number.

Journal: Journal of Clinical Microbiology

Article Title: Evaluation of antimicrobial susceptibility testing methods for Burkholderia cepacia complex isolates from people with and without cystic fibrosis

doi: 10.1128/jcm.01480-24

Figure Lengend Snippet: Comparison of error rates for CAZ, LVX, MEM, MIN, and TMP-SMX DD as compared to BMD, CF vs non-CF isolates. VMEs, MEs, and MIs for DD compared to BMD were summed for assays performed on three MHA brands (Remel, HD, and BD). The table summarizes χ 2 analyses for each antimicrobial, testing whether errors are under- or over-represented for DD performed on three different MHA brands. P -value <0.05 was considered significant, and values <0.05 are highlighted red in the table. Blue, agreement between methods; red, error between methods. #, number.

Article Snippet: For CF isolates, testing was performed from June 2022 to December 2022 using custom frozen reference BMD panels prepared by ThermoFisher with the same antimicrobial dilution ranges as listed above.

Techniques: Comparison

Example picture of A. baumannii read by reference BMD and ComASP (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).

Journal: Journal of Clinical Microbiology

Article Title: A multicenter performance evaluation of cefiderocol MIC results: ComASP in comparison to CLSI broth microdilution

doi: 10.1128/jcm.00926-24

Figure Lengend Snippet: Example picture of A. baumannii read by reference BMD and ComASP (red circle indicates MIC) (a) Reference BMD: Cefiderocol MIC = 64 µg/mL, (b) ComASP: Cefiderocol MIC = 128 µg/ml (MIC by CLSI read = 8 µg/mL).

Article Snippet: Laboratory Specialists, Inc., Westlake, OH, USA, performed testing of reference BMD for all clinical isolates and both reference BMD and ComASP (using the same initial inoculum) for challenge isolates ( ).

Techniques:

Summary of  ComASP  using 2 different reading methods compared to CLSI  BMD  MIC by bacterial species for combined clinical and challenge organisms (category agreement and errors based on FDA breakpoints) <xref ref-type= a , b " width="100%" height="100%">

Journal: Journal of Clinical Microbiology

Article Title: A multicenter performance evaluation of cefiderocol MIC results: ComASP in comparison to CLSI broth microdilution

doi: 10.1128/jcm.00926-24

Figure Lengend Snippet: Summary of ComASP using 2 different reading methods compared to CLSI BMD MIC by bacterial species for combined clinical and challenge organisms (category agreement and errors based on FDA breakpoints) a , b

Article Snippet: Laboratory Specialists, Inc., Westlake, OH, USA, performed testing of reference BMD for all clinical isolates and both reference BMD and ComASP (using the same initial inoculum) for challenge isolates ( ).

Techniques: Inhibition

Comparison of ComASP MIC distribution to BMD MIC distribution for 210 Enterobacterales* (combined clinical and challenge isolates; ComASP reading method; FDA/CLSI Breakpoints [indicated with red-dotted lines]).

Journal: Journal of Clinical Microbiology

Article Title: A multicenter performance evaluation of cefiderocol MIC results: ComASP in comparison to CLSI broth microdilution

doi: 10.1128/jcm.00926-24

Figure Lengend Snippet: Comparison of ComASP MIC distribution to BMD MIC distribution for 210 Enterobacterales* (combined clinical and challenge isolates; ComASP reading method; FDA/CLSI Breakpoints [indicated with red-dotted lines]).

Article Snippet: Laboratory Specialists, Inc., Westlake, OH, USA, performed testing of reference BMD for all clinical isolates and both reference BMD and ComASP (using the same initial inoculum) for challenge isolates ( ).

Techniques: Comparison

Comparison of ComASP MIC distribution to BMD MIC distribution for 126 P . aeruginosa (combined clinical and challenge isolates; ComASP reading method) (a) FDA Breakpoints (indicated with red lines). (b) CLSI Breakpoints (indicated with red-dotted lines).

Journal: Journal of Clinical Microbiology

Article Title: A multicenter performance evaluation of cefiderocol MIC results: ComASP in comparison to CLSI broth microdilution

doi: 10.1128/jcm.00926-24

Figure Lengend Snippet: Comparison of ComASP MIC distribution to BMD MIC distribution for 126 P . aeruginosa (combined clinical and challenge isolates; ComASP reading method) (a) FDA Breakpoints (indicated with red lines). (b) CLSI Breakpoints (indicated with red-dotted lines).

Article Snippet: Laboratory Specialists, Inc., Westlake, OH, USA, performed testing of reference BMD for all clinical isolates and both reference BMD and ComASP (using the same initial inoculum) for challenge isolates ( ).

Techniques: Comparison

Comparison of ComASP MIC distribution to BMD MIC distribution for 92 A . baumannii (combined clinical and challenge isolates; ComASP reading method) (a) FDA Breakpoints (indicated with red lines). (b) CLSI Breakpoints (indicated with red-dotted lines).

Journal: Journal of Clinical Microbiology

Article Title: A multicenter performance evaluation of cefiderocol MIC results: ComASP in comparison to CLSI broth microdilution

doi: 10.1128/jcm.00926-24

Figure Lengend Snippet: Comparison of ComASP MIC distribution to BMD MIC distribution for 92 A . baumannii (combined clinical and challenge isolates; ComASP reading method) (a) FDA Breakpoints (indicated with red lines). (b) CLSI Breakpoints (indicated with red-dotted lines).

Article Snippet: Laboratory Specialists, Inc., Westlake, OH, USA, performed testing of reference BMD for all clinical isolates and both reference BMD and ComASP (using the same initial inoculum) for challenge isolates ( ).

Techniques: Comparison

Comparison of ComASP MIC distribution to BMD MIC distribution for 40 S . maltophilia (combined clinical and challenge isolates; ComASP reading method; CLSI breakpoint [indicated with red-dotted line]).

Journal: Journal of Clinical Microbiology

Article Title: A multicenter performance evaluation of cefiderocol MIC results: ComASP in comparison to CLSI broth microdilution

doi: 10.1128/jcm.00926-24

Figure Lengend Snippet: Comparison of ComASP MIC distribution to BMD MIC distribution for 40 S . maltophilia (combined clinical and challenge isolates; ComASP reading method; CLSI breakpoint [indicated with red-dotted line]).

Article Snippet: Laboratory Specialists, Inc., Westlake, OH, USA, performed testing of reference BMD for all clinical isolates and both reference BMD and ComASP (using the same initial inoculum) for challenge isolates ( ).

Techniques: Comparison

Comparison of ComASP MIC distribution to BMD MIC distribution for Enterobacterales species that are not FDA clinically indicated (combined clinical and challenge isolates) (a) Consolidated Enterobacterales (non-clinically indicated species)*, CLSI Read, EA = 76.7% (b) Consolidated Enterobacterales (non-clinically indicated species)*, ComASP Read, EA = 95.3%.

Journal: Journal of Clinical Microbiology

Article Title: A multicenter performance evaluation of cefiderocol MIC results: ComASP in comparison to CLSI broth microdilution

doi: 10.1128/jcm.00926-24

Figure Lengend Snippet: Comparison of ComASP MIC distribution to BMD MIC distribution for Enterobacterales species that are not FDA clinically indicated (combined clinical and challenge isolates) (a) Consolidated Enterobacterales (non-clinically indicated species)*, CLSI Read, EA = 76.7% (b) Consolidated Enterobacterales (non-clinically indicated species)*, ComASP Read, EA = 95.3%.

Article Snippet: Laboratory Specialists, Inc., Westlake, OH, USA, performed testing of reference BMD for all clinical isolates and both reference BMD and ComASP (using the same initial inoculum) for challenge isolates ( ).

Techniques: Comparison